How to count aluminium joinery

Aluminium joinery is ordered in bars of profile, panes of glass and sheets. The count follows from the sizes on the plan and from a few values that only the profile system’s data sheet can give: the width of the frame and leaf profiles, the length of a bar.

1. What to take from the plan

For each type of unit note the width, the height, the number of identical units and the number of leaves. Take the profile widths and the bar length from the manufacturer’s data sheet: they are editable starting values in the tools, never a built-in reference.

Using the tool step by step

The numbered marks on the screenshots follow the order in which you use the tool. The fields are filled with an example.

  1. Aluminium Joinery Quantities: step 1
    Step 1 Enter your values: dimensions, materials and options.
  2. Aluminium Joinery Quantities: step 2
    Step 2 Read the results: quantities, costs and estimated durations, updated as you type.
  3. Aluminium Joinery Quantities: step 3
    Step 3 Explore the drawing: 3D, plan, section and detail views.

2. Profiles, glass and bars

The frame is the perimeter of the unit. Each leaf is the perimeter of its own opening, which is smaller than the unit by the frame width on each side. The glass is the leaf minus the leaf profile on each side. The length is increased by the waste percentage, then divided by the bar length and rounded up to whole bars.

Worked example: two windows of 150 × 120 cm

Two leaves each, 5 cm frame and leaf profiles, 6 m bars, 10 % waste:

  • Frame: 2 × (150 + 120) × 2 = 10.80 m, i.e. 2 bars.
  • Leaves: 70 × 110 cm each, 14.40 m in all, i.e. 3 bars.
  • Glass: 4 panes of 60 × 100 cm, 2.64 m² with waste.

Doors, shutters, extruded profiles and cladding

Stainless, steel and fire doors are counted in sheets: leaf area for each skin, and the number of sheets that cut them. A roller shutter is counted in slats (height ÷ slat height, rounded up), guide rails, winding tube and box. An extruded profile is weighed from its section: kg per metre = area in mm² × density ÷ 1000. Cladding is counted in panels with their joints, and in the support rails behind them.

What this does not cover

The count does not design the joinery: thermal, wind, acoustic and fire ratings, the profile series, the glazing build-up and the hardware come from the manufacturer and the joiner’s drawings. A fire door is only fire-rated as a certified assembly.